Loading...
hidden

View Mobile version

Startseite – Hochschule Luzern
  • Contents
  • Contact
  • Login
  • En
Search
  • Engineering and Architecture
  • Business
  • Computer Science
  • Social Work
  • Design, Film and Art​
  • Music
  • Health Sciences
  • Degree Programs
  • Continuing Education
  • Research
  • International
  • Institutes
  • About us
  • Building Physics Lab
  • Geotechniklabor
  • Betonlabor
  • Fassadenprüfstand
  • Glas- und Fassadenprüfungen
  • Optiklabor
  1. Lucerne School of Engineering and Architecture Lucerne School of Engineering and Architecture
  2. About us About us
  3. Building and Construction Building and Construction
  4. Building Envelopes and Civil Engineering Building Envelopes and Civil Engineering
  5. Infrastructure Infrastructure
  6. Building Physics Lab Building Physics Lab

Building Physics Lab

The performance of a building envelope emerges from the interaction between its construction, climate and use. In our Building Physics Lab, we integrate multi-criteria simulations, monitoring and in-situ measurements into digital twins to assess and optimise real-world performance.

Messgerät für In-situ g-Wert-Messung am Fenster angebracht
hidden

In-Situ g-Value Measurement

How much solar energy enters a room through a window? The total solar energy transmittance (g-value or Solar Heat Gain Coefficient SHCG) of glazing is typically determined through laboratory testing or calculation. However, under real-world conditions, factors such as solar shading, ageing, vegetation and changing solar angles can lead to significant deviations from these values.

The Competence Center for Building Envelopes and Civil Engineering has developed a mobile measurement system for the experimental determination of the total solar energy transmittance (g-value or SHGC) of glazing under real environmental conditions, directly on existing buildings. Measurements are performed in-situ, without removing the glazing and using a non-destructive method.

more

The method combines the measurement of solar radiation and heat flux with digital analysis: It records the incident and transmitted solar radiation as well as the heat flux at the interior glass surface. A digital twin models the transient thermal behaviour of the glazing and allows a direct comparison between measurements and simulations – the basis for value assessments.

Measurement Method
​
The core of the measurement method is a temperature-controlled heat flux sensor plate. Peltier elements maintain it at room temperature, ensuring that no temperature-induced heat exchange occurs. The measured heat flux thus directly corresponds to the solar heat gain, the transmitted solar radiation plus the secondary heat emission from the heated glass pane. A multi-zone-controlled protective ring around the measurement area prevents lateral heat fluxes and ensures a one-dimensional heat flux. Two wireless pyranometers simultaneously measure solar radiation on the exterior and interior sides of the glazing system.

The measurement data is analysed using a digital twin of the tested glazing assembly, which simulates the total energy transmittance (g-value) and the solar transmittance (τ) under real conditions. The model accounts for solar position and angle of incidence and uses weather station data to separate the incident solar radiation into direct and diffuse components. This approach enables the characterization of angle-dependent and light-directing systems, such as louvers, expanded metal meshes or green facades.

Application
​
The measurement system is designed for the experimental assessment of the energy performance of installed glazing under real operating conditions. It is a non-standardised measurement method. The results complement standard-based performance values but do not replace normative testing by an accredited body. For the measurement, the exterior side of the glazing must be accessible to allow installation of the external pyranometer. Approximately half a day with ideally unobstructed direct sunlight on the façade should be scheduled. The measurement is therefore weathedependent.

Technical Specifications:

  • Measurement principle: Peltier-controlled heat flux measurement plate with a multi-zone guard ring, mounted on the room-facing side of the glazing
  • Measurement area: 125 × 125 mm
  • Main unit: Dimensions: 30 × 30 cm without suction cups (58 × 30 cm including suction cups); weight: 12 kg; mounting: suction cups; power supply: 230 V AC
  • Measured parameters: Total heat flux (W/m²), global solar irradiance on the façade plane and transmitted solar irradiance (W/m²), temperatures of the measurement plate, guard ring and indoor air temperature (PT100), outdoor temperature and relative humidity
  • Solar radiation measurement: Kipp & Zonen CMP3 pyranometer (thermopile, ISO 9060:2018 Spectrally Flat Class C, 300–2800 nm), battery-powered, wireless data transmission via Bluetooth Low Energy
  • Data recording: 1 second interval, data storage on SD card, live data transmission
  • Measurement duration: Approx. 3.5 h per configuration under direct sunlight, including approx. 30 min stabilisation phase and a 2.5 h evaluation window
  • Data evaluation: Mean values calculated over a quasi-steady-state evaluation window, comparison with the digital twin of the glazing system and reference values according to EN 410 / EN 673
  • Results: Total solar energy transmittance (g-value) and solar transmittance (τ) under actual operating conditions, including angle of incidence and direct/diffuse radiation components; measured vs. simulated time series; measurement report including measurement uncertainty [± … %]

Validation Example (Triple-Glazed Acoustic Insulating Glass): 
​
Over a 2.5 h evaluation window, the simulation (digital twin) underestimates the measured solar transmittance by an average of 3.5% and the measured total heat flux by 3.1%. The resulting g-value is 49.1%, compared to 49.0% specified in the manufacturer's datasheet.

Note:
The g-value under actual operating conditions depends on the angle of incidence, the distribution of solar radiation, and climatic conditions. It is therefore not directly comparable to the standardised g-value, which is determined for normal incidence under defined boundary conditions.

In addition to its use in research projects and teaching, we offer experimental measurements as a service. These measurements can support the development and optimisation of complex glazing and solar shading systems. We also provide architects, engineers and building owners with measurement data to assess the performance of existing glazing systems, particularly when product data is no longer available or when the effects of solar shading and façade greening need to be quantified.

 

Prof. Dr. Susanne Gosztonyi

Professor, Head of Research Group Building Envelopes and Energy

+41 41 349 35 65

Show email

Daniel Plörer

Research Associate

+41 41 349 39 85

Show email

Thomas Wüest

Senior Research Associate

+41 41 349 38 42

Show email

More information

  • Blog Post (Only in German)

Publications

  • Fachartikel «Der reale g-Wert bei verbauten Verglasungen» (FASSADE 01/2026, S. 46–49) (Only in German) 
  • Fachartikel «Erfahrungen zu g-Wert-Messungen» (FASSADE 04/2026, S. 48–53) (Only in German) 
  • Hauer, M.; Plörer, D.; Gosztonyi, S.; Pfluger, R. (2026) Innovative Messmethode zur In-situ-Charakterisierung von g-Werten an Gebäudebestandsfassaden. Bauphysik 48, H. 3, S. 267–274.

About us

  • Building Envelopes and Civil Engineering
  • Team
  • Contact and direction
FH Zentralschweiz

Social media links

  •  Instagram
  •  LinkedIn
  •  TikTok
  •  Facebook
  •  YouTube
  •  Flickr

Contact

Logo Lucerne School of Engineering and Architecture

Lucerne School of Engineering and Architecture


Technikumstrasse 21
6048 Horw

+41 41 349 33 11

technik-architektur@hslu.ch

Direct entry

  • For Students
  • Weiterbildungsinteressierte
  • For Employees
  • Media Relations

Quick link

  • People finder
  • Jobs & Karriere
  • Organisation des Departements Technik & Architektur
  • Diversity
  • Hiring Rooms
  • Library of Engineering and Architecture

Static links

  • Newsletter
  • Data protection notice
  • Publishing Acknowledgements
Logo Swissuniversities

QrCode

QrCode